Our Honors

CE,GS,ROHS,CCC & CQCAll Certified !Products has been sold to 176 countries.Golden Supplier !

Germany Standard Series Catalog:

Heat-resistant wire with PVC insulation. - FLYW

Heat-resistant wire with PVC insulation.
Heat-resistant wire with PVC insulation. The conductor and drain, DIN 40500 Part 4 .The insulation was PVC according to VW60306.

Heat-resistant low-tension wire with PVC insulation - FLRYWF

Heat-resistant low-tension wire with PVC insulation
Heat-resistant low-tension wire with PVC insulation, The conductor and drain wire was stranded with soft-annealed copper wires specified in DIN 40500 Part 4 ,specified in DIN 72551 Part 6 type A .The insulation was PVC according to ISO 6722 Part 2 class B .

Cold-resistant PVC wire with increased flexibility - FL2X

Cold-resistant PVC wire with increased flexibility
Cold-resistant PVC wire with increased flexibility,The conductor and drain wire was stranded with soft-annealed copper wires specified in DIN 40500 Part 4 .Performance was specified in VW60306.

Single-Core and thin insulation low-tension wire for automobiles - FLRY-A

Single-Core and thin insulation low-tension wire  for automobiles
Single-Core and thin insulation low-tension wire for automobiles,The conductor was stranded with soft-annealed copper wires specified in DIN 40500.4 .The conductor of A mode is conform to DIN 72551.6 Products performance is conform to DIN 72551.5、VW 60306 .

Single-Core and thin insulation low-tension wire for automobiles - FLRY-B

Single-Core and thin insulation low-tension wire  for automobiles
Single-Core and thin insulation low-tension wire for automobiles,The conductor was stranded with soft-annealed copper wires specified in DIN 40500.4 .The conductor of B mode is conform to DIN 72551.6. Products performance is conform to DIN 72551.5、VW 60306 .

Crosslinked PVC insulation low-tension cables for automobiles. - FLRX-B

Crosslinked PVC insulation low-tension cables for automobiles.
Crosslinked PVC insulation low-tension cables for automobiles. The conductor and drain wire was stranded with soft-annealed copper wires specified in DIN 40500 Part 4 . The conductor of B mode is conform to DIN 72551. Performance was specified in ISO6722 type B.

Single-Core low-tension cables with thermoplastic elastomer - FLR13Y-A

Single-Core low-tension cables with thermoplastic elastomer
Single-Core low-tension cables with thermoplastic elastomer, The conductor and drain wire was stranded with soft-annealed copper wires specified in DIN 40500 Part 4 ,specified in VW60306 type A . Products performance is conform to VW 60306 .

Wrapped Shielded, single-core PVC insulation PVC sheath low-tension cable - FLRYDY

Wrapped Shielded, single-core PVC insulation PVC sheath low-tension cable
Wrapped Shielded, single-core PVC insulation PVC sheath low-tension cable, PVC insulation is conform to ISO6722 Part 2 class A. The shielding was spiraled with soft-annealed copper wires or with tin coated soft-annealed copper wires specified in DIN 40500.PVC sheath is conform to ISO6722 Part 2 class A.

PVC insulation and PVC sheathed low-tension cable with aluminium-coated polyester foil shielded - FLRYY-A

PVC insulation and PVC sheathed low-tension cable with aluminium-coated polyester foil shielded
PVC insulation and PVC sheathed low-tension cable with aluminium-coated polyester foil shielded, The conductor construction according to DIN72551 type A .The conductor was stranded with soft-annealed copper wires specified in DIN 40500 Part 4.The performance specified in ISO6722 class B and specified in ISO14572.

Multi-core TPE-E insulation and TPE-U sheathed low-tension cable - FLR13Y11Y

Multi-core TPE-E insulation and TPE-U sheathed low-tension cable
Multi-core TPE-E insulation and TPE-U sheathed low-tension cable, The conductor was stranded with soft-annealed copper wires or with tin coated soft-annealed copper wires specified in DIN 40500.The insulation was thermoplasticity polyester specified in ISO6722.2 Level C. The sheath was thermoplasticity polyurethane.

PVC insulation and PVC sheathed low-tension cable with aluminium-coated polyester foil shielded - FLRYBY

PVC  insulation and PVC sheathed  low-tension cable with aluminium-coated polyester foil shielded
The conductor was stranded with soft-annealed copper wires specified in DIN 40500.The insulation was PVC specified in DIN72551. The nakedness wire was stranded with tin coated soft-annealed copper wires specified in DIN 40500. And according to DIN72551 Part 6 type A. The shielding was foil shield of aluminium-coated polyester foil.

Multi-core spun shielded PVC insulation PVC sheathed low-tension cable. Car communication cable - FLRYCY

Multi-core spun shielded PVC  insulation PVC sheathed  low-tension cable. Car communication cable
The conductor according to DIN72551 Part 6 type B .The conductor was stranded with soft-annealed copper wires specified in DIN 40500.The insulation was PVC specified in ISO6722 Part 2 class A. The shielding was braided with soft-annealed copper wires or with tin coated soft-annealed copper wires specified in DIN 40500.